8. CONNECTION TO SETTING AND DISPLAY UNIT
B–63173EN/03
258
Indicator 7.2″ LCD, 40 characters by 16 lines
Power supply 24 VDC "10%, 1.0 A
(including an instantaneous value and ripple)
External
dimensions
410 (W) x 235 (H) x 235 (D) mm
(including the cable winding section)
Weight 7.0 kg (excluding connection cables)
Drawing number A02B–0166–C271#R (English keys)
A02B–0166–C271#S (Symbolic keys)
NOTE
This detachable LCD/MDI does not support the picture
display function.
1) Inter–unit connection diagram
Connector
panel
Power
Mate
Detach-
able LCD/
MDI unit
Connection
panel
24 VDC
power
supply
24VDC"10%
1.0A
Cabinet
J132
J127
J128
J143
(See item (4))
CA50
JD41
(1)The total length of the cables (J127, J128, and J143) between the
detachable LCD/MDI unit and Power Mate must not exceed 50 m.
(2)Cables J127, J128, and J132 also serve as a 24 VDC power supply line
for the detachable LCD/MDI unit. The 24 VDC power is subject to
a voltage drop corresponding to the total resistance of the 24V line and
0V line. Taking this voltage drop into consideration, determine the
cable length so that 24 VDC "10% is available at connector CA50 of
the detachable LCD/MDI unit.
(3)Use cable J143 for termination on the Power Mate side.
8.5.2
Specifications
8.5.3
Detachable LCD/MDI
Unit Connected to One