7. CONNECTION TO FA NETWORKS
B–63173EN/03
226
NOTE
1 For DeviceNet, refer to ”FANUC DeviceNet Board
Operator’s Manual B–63404EN”.
2 The DeviceNet board cannot be used with the
PROFIBUS–DP board at the same time.
3 The DeviceNet master board and DeviceNet slave board
uses the same printed circuit board specifications, and only
the difference between these boards is the jumper position
of the setting pin TM1 on the boards. (The unit specification
of the master board is different from that of the slave board.)
TM1 is factory–set by FANUC. The relationship between
the DeviceNet master board B and DeviceNet slave board
B is the same as the relationship between the DeviceNet
master board and DeviceNet slave board.
4 The DeviceNet board and DeviceNet board B must be
inserted and removed according to the predetermined
procedure.
5 When the DeviceNet master board and DeviceNet slave
board are used, depending on the axis control card
specified, the communication connectors of the DeviceNet
boards may interfere with the connector of the axis control
card. When such interference occurs, and when there is no
special reason for using the DeviceNet master board and
DeviceNet slave board, use the DeviceNet master board B
and DeviceNet slave board B.
6 The ambient temperature for operating the control unit
including DeviceNet boards must be within the range from
0°C to 50°C.
DeviceNet interface connector
5 4 3 2 1
7.7.2
Connection
DeviceNet board