6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
B–63173EN/03
198
The power to the FSSB I/O module must be supplied from an external
24–VDC stabilized power source.
FSSB I/O module External power source
Regulated 24–VDC
power source
GND1 is the frame ground of the FSSB I/O module.
Connect GND1 to the ground plate of the cabinet using
the same Faston terminal (A02B–0166–K330) as that
used for the Power Mate i.
Cable
CP11A
Japan AMP
1–178288–3 (housing)
1–175218–5 (contact)
External power source
Recommended cable specification :
A02B–0124–K830 (5m)
The external power source side of the cable has an M3 crimp terminal.
The 24–VDC power input to CP11A can be extracted from CP11B. The
connection of CP11B is the same as that of CP11A.
(1)When the cable is run outside the cabinet, use a common shield cable.
34 pin cable with shild (soldering type)
OKI DENSEN CO., LTD. SFX–S 34–7/0.127 3030–SV
(20266) K
FANUC SPECIFICATION A66L–0001–0308#S34S
Clamp the cable shield with the cable clamp on the grounding plate of
the cabinet on the I/O module side.
When the cable used is not a shield cable, it must be used only within
the cabinet.
(2) Pin No. of connector
Prevent key
Pin mark
A
B
The near side to prevent key is an
A side.
The opposite side is a B side.
The near pin to pin mark is No. A1.
To P.C.B.
17 (From cable side) 3 2 1
Upper
side
(3) Ensure that the cable is securely plugged into the unit. Otherwise,
problems such as DI/DO signal transfer errors may occur.
6.12.5
Connecting the Power
6.12.6
Connection Cable to
I/O