B-65325EN/01 TROUBLESHOOTING FOR βi SVPM 3.TROUBLESHOOTING AND ACTION
- 129 -
3.1 COMMON TO SERVO AND SPINDLE UNITS
3.1.1 STATUS2 Alarm Code -
STATUS1 Alarm Code 30
SVPM
(1) Meaning
The main circuit power module (IPM) has detected an abnormal
condition.
(2) Cause and troubleshooting
(a) Control supply voltage decrease of the power module (IPM)
→ Replace the power unit.
(b) Input supply voltage imbalance
→ Check the input power supply specification.
(c) The specification of the AC reactor does not match the
SVPM in use.
→ Check the SVPM and the specification of the AC
reactor.
(d) IPM failure
→ Replace the IPM.
3.1.2 STATUS2 Alarm Code -
STATUS1 Alarm Code 59
(1) Meaning
A cooling fan for the control circuit has stopped.
(2) Cause and troubleshooting
This alarm is not issued in the SVPM.
If this alarm is issued, the SVPM or SVPM control printed circuit
board may be defective.
Replace the SVPM or SVPM control printed circuit board.
3.1.3 STATUS2 Alarm Code -
STATUS1 Alarm Code 58
(1) Meaning
The temperature of the main circuit heat sink has risen
abnormally.
(2) Cause and troubleshooting
(a) Cooling fan broken
Check whether the cooling fan rotates normally.
→ Replace it.
(b) Dust accumulation
→ Clean the cooling system with a vacuum cleaner or the
factory air blower.
(c) Overload
→ Examine the operating conditions.