3.TROUBLESHOOTING AND ACTION TROUBLESHOOTING FOR βi SVPM B-65325EN/01
- 152 -
(d) The belt slips.
The belt between the spindle and motor may slip. Clean the
pulley, and tighten the belt again.
3.4.7 Alarm Code 15
This alarm is issued only when output switching control or spindle
switching control is used.
The SVPM does not support output switching control and spindle
switching control.
(1) Troubleshooting when this alarm is issued
(a) Avoid performing output switching control and spindle
switching control.
(b) The SVPM is faulty.
Replace the SVPM or SVPM control printed circuit board.
3.4.8 Alarm Code 18
A sum check is abnormal.
If this alarm is issued, replace the SVPM or SVPM control
printed-circuit board.
3.4.9 Alarm Codes 19 and 20
The offset voltage of the phase U (alarm code 19) or phase V (alarm
code 20) current detection circuit is excessively high. A check is made
when the power is turned on.
If this alarm is issued, replace the SVPM. If this alarm is issued
immediately after the SVPM control printed circuit board is replaced,
check the plugging of the connectors between the power unit and
SVPM control printed circuit board.
3.4.10 Alarm Code 21
The specified polarity of the position sensor is incorrect.
Troubleshooting when this alarm is issued
(a) Check the position sensor polarity parameter (bit 4 of parameter
No. 4001).
(b) Check the feedback cable of the position sensor.