3.TROUBLESHOOTING AND ACTION TROUBLESHOOTING FOR βi SVPM B-65325EN/01
- 160 -
3.4.24 Alarm Codes 52 and 53
The synchronization signal (ITP) in communication data transferred to
and from the CNC stopped.
Troubleshooting when this alarm is issued
(a) The SVPM is faulty.
Replace the SVPM or SVPM control printed circuit board.
(b) The CNC is faulty.
Replace the board or module related to the serial spindle.
3.4.25 Alarm Code 54
A large current flowing in the motor for a long time was detected.
Troubleshoot as in the case of alarm code 29.
3.4.26 Alarm Code 73
The signal of the motor sensor is disconnected.
(1) If this alarm is issued when the motor is deactivated
(a) The setting of a parameter is incorrect.
Referring to "FANUC AC SPINDLE MOTOR αi/βi series
Parameter Manual (B-65280EN)," check the parameter for
sensor setting.
(b) The cable is disconnected.
Replace the cable.
(c) The sensor is not adjusted correctly.
Adjust the sensor signal. If the sensor signal cannot be
adjusted correctly, or the sensor signal is not observed,
replace the connection cable and sensor.
(d) The SVPM is faulty.
Replace the SVPM or SVPM control printed circuit board.
(2) If this alarm is issued when the cable is moved (as in the case
where the spindle moves)
The conductor may be broken. Replace the cable. If coolant has
penetrated into the connector, clean the connector.
(3) If this alarm is issued when the motor rotates
(a) The shielding of the cable between the sensor and the SVPM
is faulty.
Check the shielding of the cable.
(b) The signal cable is bundled with the servo motor or spindle
motor power lead.
If the cable between the sensor and the SVPM is bundled
with the servo motor or spindle motor power lead, separate
them from each other.
S
V
P
M
Sensor
The cable is
connected to the
pin specified in the
Descriptions on the
sensor side.
The cable is
connected to
pin 10 on the
SVPM side.
Shielded cable
MZi sensor