12. NC COMMAND PROGRAM (PMC-SC)
B–61863E–1/06
PMC LIBRARY
284
SC/SC3/SC4 NB/NB2 16i/18i/21i 15i–A
f f
[Name]
pl_nc_dwnstart
[Description]
Executes the processing to start outputting (downloading) the data of
the NC command to be registered.
[Format]
ret = pl_nc_dwnstart( ) ;
short ret ;
[Input]
______
[Output]
______
[Returns]
ret Complete code (–1, 0, 7)
–1 : The request for starting output of the data of the NC command
to be registered was rejected. This completion code is returned
because the command was issued while the NC was in the
background edit mode, upload mode, MDI mode, or alarm
state.
0 : The NC has normally terminated preparation to start
downloading.
7 : The memory protection for the NC is enabled.
[Remarks]
______
12.1
EXECUTING
PROCESSING TO
START OUTPUTTING
(DOWNLOADING)
THE DATA OF THE
NC COMMAND TO BE
REGISTERED