5. TUTORIAL
B–61863E–1/06
GENERAL
26
(4) Execution
At first assign the tool number (No.1, No.2, ..) to the address (D8,
D16, D24, D32) on the PMCPRM screen. In the sample program each
address is defined as shown below. The data type is long integer.
D0 Tool number specification
D4 Over all run time
D8 Tool No.1
D12 Run time of Tool No.1
D16 Tool No.2
D20 Run time of Tool No.2
D24 Tool No.3
D28 Run time of Tool No.3
D32 Tool No.4
D36 Run time of Tool No.4
D40 Not in use
D44 Run time for other Tool No.
Press the softkey [RUN].
The run time of the tool number(s) specified with DO will be counted
up and displayed at the reserved output. A specified tool number other
than 1 to 4 will be count up and displayed at D44. Over all run time
of each tool will be added and displayed at D4.
If user switches to PMCMDI screen nothing will be displayed.
These data are shown at PMCPRM screen.