2.SIGNAL DESCRIPTIONS HANDLING B-65395EN/01
- 70 -
NOTE
1 To perform positioning for the skip function, bit 0
(HENB) of parameter No. 017 must be set to "1"
(use the skip function).
2 It is possible to specify, using an appropriate
parameter, whether to retain the previous skip
measurement data or record the specified end point
coordinates if, during the execution of positioning for
the skip function (peripheral equipment
control/direct command), the skip signal (HDI) is not
input and the end point is reached. If bit 2 (SPCO)
of parameter No. 17 is "0", the previous skip
measurement data is recorded; if "1", the specified
end point coordinates.
3 If reading skip measurement data with peripheral
equipment control, confirm the completion of
positioning for the skip function (OPC4 = 1)
beforehand.
4 If, during the execution of positioning for the skip
function (peripheral equipment control/direct
command), the execution is interrupted due to an
external reset, emergency stop, alarm, etc., no skip
measurement data is updated.