B-65395EN/01 HANDLING 2.SIGNAL DESCRIPTIONS
- 53 -
(3) Rapid traverse override signals ROV1 and ROV2
[Classification] Output signal <Yy+7#4 to #5> (peripheral equipment control interface)
<Yy+2#4 to #5> (direct command interface)
[Function] The host specifies override for rapid traverse.
[Operation] The following table lists the override amounts.
ROV2 ROV1 Override value
0 0 100%
0 1 50%
1 0 25%
1 1 F0
NOTE
F0 is a value specified in parameter No. 061.
(4) Incremental feed signal MP1, MP2
[Classification] Output signal <Yy+7#4 to #5> (peripheral equipment control interface)
[Function] Used to select the manual handle feed magnification of the servo
amplifier module.
[Operation] In manual handle mode, the servo amplifier module drives the motor for
the pulses of the input manual pulse generator times the magnification
selected with this signal.
MP1 MP2
Amount of travel per graduation of the
manual pulse generator
0 0 1 user unit
0 1 10 user units
1 0 100 user units
1 1
(M/N) user unit
(M = Parameter No. 62, N = Parameter No. 63)
NOTE
1 This signal is effective if bit 5 (MP) of parameter No.
5 of the servo amplifier module is 1.
2 This signal is effective in manual handle mode only.
3 This signal shares the same bits with the rapid
traverse override signal. In manual handle mode,
these bits are for the incremental feed signal; in
modes other than manual handle mode, they are for
the rapid traverse override signal. Before switching
from manual handle mode to another mode, this
signal must be returned to such a setting that the
bits are for the rapid traverse override signal.