B-65395EN/01 HANDLING 3.PERIPHERAL EQUIPMENT CONTROL
- 115 -
Interval 1 (315° ≤ Current position < 45°) → Turret/magazine number 1
Interval 2 (45° ≤ Current position < 135°) → Turret/magazine number 2
Interval 3 (135° ≤ Current position < 225°) → Turret/magazine number 3
Interval 4 (225° ≤ Current position < 315°) → Turret/magazine number 4
• A magazine number boundary is regarded as the midpoint
between two adjacent magazines. If the current position is on
a boundary, the magazine number on the + side is output.
• That the number is constantly output does not mean that
response data is automatically updated; response data needs
to be read in synchronization with the host. Before reading
response data, use ABSWT (X
X+1
#0) and ABSRD (Y
y+1
#4)
to update the response data. For details of how to do this, see
Section 3.8, "Upgrading of the Response Data Read
Function".
(2) A signal reports on whether the current position is in the
permissible magazine position range.
<1> If the current position is in the permissible magazine position range
→ MINP signal (X
X+6
#7) output
<2> If the current position is not in the permissible magazine position range
→ If it out of the permissible range in the + direction → +MOR signal
(X
X+6
#6) output
→ If it is out of the permissible range in the direction → -MOR signal
(X
X+6
#5) output
• For example, if one rotation about the rotation axis is by
"360°" and the number of magazine/turret numbers
(parameter No. 068) is "4", each signal is output as shown in
Fig. 2.