B-65395EN/01 APPENDIX B.PARAMETER LIST
- 251 -
Override value
ROV2 ROV1
RVF2=0 RVF2=1
0 0 100% 100%
0 1 50% F1
1 0 25% F2
1 1 F0 F0
NOTE
For F0, F1, and F2, set actual feedrates in
parameters No. 061, No. 066, and No. 067,
respectively.
CSMZ Specifies whether to enable the output signal SMZX (Yy+7#5) of a
direct command, as follows:
0 : Disabled.
1 : Enabled.
No
055
Rapid traverse linear acceleration/deceleration time constant or
rapid traverse bell-shaped acceleration/deceleration time constant
T1
Rapid traverse exponential acceleration/deceleration time constant
[Size] 2-byte
[Unit of data] msec
[Valid data range] 0 to 4000
[Standard value] 100
[Description] Specifies a rapid traverse acceleration/deceleration time constant. The
acceleration/deceleration time constant to be used is determined
depending on whether bit 0 of parameter No. 002 (RPDE) and rapid
traverse bell-shaped acceleration/deceleration time constant T2 are set.
No
056
Rapid traverse bell-shaped acceleration/deceleration time constant
T2
[Size] 2-byte
[Unit of data] msec
[Valid data range] 0 to 512
[Standard value] 100
[Description] Specifies rapid traverse bell-shaped acceleration/deceleration time
constant T2.