B.PARAMETER LIST APPENDIX B-65395EN/01
- 244 -
EPEXA, EPEXB Specify the operation that is to occur if the axis movement rate
determined according to external pulses exceeds the feedrate upper
limit specified in parameter No. 043.
EPEXB EPEXA Description
0 0
The feedrate is clamped to the parameter-specified
value, and the excessive pulses are treated as
accumulated pulses.
If the number of accumulated pulses exceeds 99999999,
the excessive pulses are discarded.
0 1 Alarm 291 is issued, leading to deceleration and stop.
1 0
The feedrate is clamped to the parameter-specified
value, and the excessive pulses are discarded.
1 1 Alarm 291 is issued, leading to deceleration and stop.
No
068 Number of magazines/turrets
[Size] 2-byte
[Valid data range] 1 to 9999
[Standard value] 0
[Description] Sets up the number of magazines/turrets.
No
140 Machine coordinate of the reference position
[Size] 4-byte
[Unit of data] User-specified unit
[Valid data range] 0 to ±99999999
[Standard value] 0
[Description] Sets up the machine coordinate for the reference position.
When setting of the reference position, either without dogs or externally,
is completed, the machine coordinate is preset to the value specified in
the parameter.
No
141 Amount of movement per rotation axis revolution
[Size] 4-byte
[Unit of data] User-specified unit
[Valid data range] 0 to 99999999
[Standard value] 0
[Description] Specifies an amount of movement per revolution for the rotation axis. If
0 is specified, the amount of movement is assumed to be 36000.