B-65395EN/01 HANDLING 3.PERIPHERAL EQUIPMENT CONTROL
- 77 -
(3) Upon completion of the movement, the servo amplifier module
returns the operation completion signal OPC 3 to the host NC, and
also outputs the clamp command signal.
(4) When clamp completion notification is sent from the host NC, the
servo amplifier unit returns response data (turret/magazine
number or coordinates) and the operation completion signal OPC
4, and is placed in the start enabled state.
(5) Upon receipt of the operation completion signal OPC 4, the PMC
on the host NC returns the FIN signal.
(6) If an alarm is issued while the servo amplifier module is executing
an instruction, the AL signal is output. So, the PMC on the host
NC is to perform processing such as alarm indication. In this case,
the number of alarms and alarm numbers can be included in the
response data by setting the DSAL signal [Subsection 2.3.13.(9)]
to 1.
Supplementary information
1) The unclamp/clamp command signal and state signal are used for
communication with the host.
2) Whether the unclamp/clamp state signal is to be checked is
specified by setting bit 2 (IGCP) of parameter No. 003. When
IGCP is set such that no check is to be made, the operation
completion signal OPC 2 and operation completion signal OPC 3
are not output.
3) Use parameter No. 167 to set the period between the servo
amplifier module being turned on and the output of the unclamp
command signal. Use parameter No. 168 to set the period between
the clamp command signal being output and the servo amplifier
unit being turned off.
4) The ST signal can be accepted in the start enabled state only.
5) The start enabled state is that state in which the STL signal is off.