4.DIRECT COMMANDS HANDLING B-65395EN/01
- 136 -
4.4 DETAILS OF DIRECT COMMAND FUNCTIONS
4.4.1 Signal Operation Commands
(1) Setting and releasing the torque limit enable signal
The host specifies the setting and release of the torque limit enable
signal.
• Instruction command format
#7 #6 #5 #4 #3 #2 #1 #0
Yy+4 Control flag 1
Yy+5 0 0 0 0 1 1 0 0 (0x0C)
Yy+6 0 0 0 1 0 0 0 SET
SET = 0 : Releases the torque limit enable signal.
SET = 1 : Sets the torque limit enable signal.
• Response command format
This command has no response data.
It only inverts EBSY.
(2) Specifying the torque limit value
The host specifies the torque limit value when the torque limit is
enabled.
• Instruction command format
#7 #6 #5 #4 #3 #2 #1 #0
Yy+4 Control flag 1
Yy+5 1 0 0 1 0 0 0 1 (0x91)
Yy+6 0 0 0 1 0 0 0 0
Yy+7
Yy+8
Torque limit value
Torque limit value : 0 to 7282
Setting value = Torque limit value [%] × (7282/100)
• Response command format
This command has no response data.
It only inverts EBSY.
NOTE
1 Set bit 2 (IEBL) of parameter No. 0010 to "1" to
enable the torque limit function.
2 After the release command, the system returns to
the torque limit value set in parameter No. 108.
3 A torque limit value of 0 means 100% (disabled).