B-65395EN/01 HANDLING 4.DIRECT COMMANDS
- 153 -
(12) Reading the torque command
This function reads from the host the torque command of the servo
amplifier module.
● Instruction command format
#7 #6 #5 #4 #3 #2 #1 #0
Yy+4 Control flag 1
Yy+5 1 0 0 1 0 1 1 0 (0x96)
Yy+6 0 0 0 0 0 0 0 1
● Response command format
#7 #6 #5 #4 #3 #2 #1 #0
Xx+4 Control flag 2
Xx+5 1 0 0 1 0 1 1 0 (0x96)
Xx+6 Reserved Execution result
Xx+7
Xx+8
Xx+9
Xx+10
Torque command data (DWORD type)
The maximum value of the torque command is 6554.
The least significant bit of the torque command means
the torque limit arrival signal.
The least significant bit of the torque command =
0: The torque limit has not been reached.
1: The torque limit has been reached.
(13) Reading the actual speed
This function reads from the host the actual speed of the servo
amplifier module.
● Instruction command format
#7 #6 #5 #4 #3 #2 #1 #0
Yy+4 Control flag 1
Yy+5 1 0 0 1 0 1 1 1 (0x97)
Yy+6 0 0 0 0 0 0 0 1
● Response command format
#7 #6 #5 #4 #3 #2 #1 #0
Xx+4 Control flag 2
Xx+5 1 0 0 1 0 1 1 1 (0x97)
Xx+6 Reserved Execution result
Xx+7
Xx+8
Xx+9
Xx+10
Actual speed data (DWORD type)
Unit of data : min
-1