3.PERIPHERAL EQUIPMENT CONTROL HANDLING B-65395EN/01
- 84 -
3.4.5 Positioning Control (Absolute/Incremental Specification, for
Skip Function)
Processing
by PMC
ST signal
Command data 2 (amount of travel or specified coordinates)
Command data 1 (feedrate code)
(2) Operation completion signal OPC 1: Unclamp command signal (UCPC2)
uto mode
Start enabled state
Servo amplifier module
operation state
(1) O0001
:
T xx
Host NC
CNC PMC
Function code = 5, 6, 8
(5) Alarm indication
L signal and the number of alarms/
alarm numbers
(4)
Move command execution, automatic operation start state
Operation completion signal OPC 3: Clamp
command signal (UCPC2)
(UCPS2=1) Operation completion signal OPC2
(UCPS2=0) Response data (coordinates)
FIN Processing
by PMC
Processing
by PMC
(3) Unclamp completion
Clamp completion
Operation completion signal OPC 4
Start enabled
state
larm state occurrence
When execution has
terminated
abnormally
(1) The PMC on the host NC sets a function code, command data 1,
and command data 2, then sends the ST signal to the servo
amplifier module. Upon receipt of the data, the servo amplifier
module returns the operation completion signal OPC 1 to the host
NC, and also outputs the unclamp command signal to the host NC.
(2) When unclamp completion notification is sent from the host NC,
the servo amplifier unit returns the operation completion signal
OPC 2 to the host NC, then starts movement.
If positioning for the skip function (function code 8) is issued, the
skip function with the skip signal (HDI) is enabled. When HDI is
input, axis movement is stopped immediately.