B-65395EN/01 HANDLING 3.PERIPHERAL EQUIPMENT CONTROL
- 125 -
3.10.3 Signal
3.10.3.1 Signal on the servo amplifier module
7 6 5 4 3 2 1 0
Yy+0 MD4 MD2 MD1
Yy+7 MP2 MP1
Mode select signals MD1, MD2, and MD4
[Classification] Output signal <Yy+0#0 to #2>
[Function] These signals are used to select an operation mode.
[Operation] These signals are used to select the manual handle feed of the servo
amplifier module.
MD1 MD2 MD4 Remarks
0 0 1 Manual handle feed (HANDLE)
NOTE
1 Enter manual handle mode before rotating the
manual pulse generator.
2 Do not switch modes during the manual handle
operation of the servo amplifier module.
Incremental feed signal MP1 and MP2
[Classification] Output signal <Yy+7#4,#5>
[Function] These signals are used to select a magnification for the manual handle
feed of the servo amplifier module.
[Operation] In manual handle mode, the servo amplifier module drives the motor for
the input pulses of the manual pulse generator times the magnification
selected with these signals.
MP1 MP2
Amount of travel per graduation of the
manual pulse generator
0 0 1 user unit
0 1 10 user units
1 0 100 user units
1 1
(M/N) user units
(M = Parameter No. 62, N = Parameter No. 63)