4.DIRECT COMMANDS HANDLING B-65395EN/01
- 152 -
(i) Reading the actual speed 0x0F
● Data specification code for continuous read
#7 #6 #5 #4 #3 #2 #1 #0
0 0 0 0 0 1 1 1 1 (0x0F)
1 0 0 0 0 0 0 0 1
● Continuous read data format
#7 #6 #5 #4 #3 #2 #1 #0
0 0 0 0 0 1 1 1 1 (0x0F)
1 Reserved Execution result
2
3
4
5
Actual speed data (DWORD type)
Unit: min
-1
(11) Reading the motor current value
This function reads the motor current value from the host.
● Instruction command format
#7 #6 #5 #4 #3 #2 #1 #0
Yy+4 Control flag 1
Yy+5 1 0 0 1 0 1 0 1 (0x95)
Yy+6 0 0 0 0 0 0 0 1
● Response command format
#7 #6 #5 #4 #3 #2 #1 #0
Xx+4 Control flag 2
Xx+5 1 0 0 1 0 1 0 1 (0x95)
Xx+6 Reserved Execution result
Xx+7
Xx+8
Xx+9
Xx+10
Motor current value data (DWORD type)
The motor current value means the maximum current
value of the amplifier when it is 6554.