B-65395EN/01 APPENDIX B.PARAMETER LIST
- 265 -
No #7 #6 #5 #4 #3 #2 #1 #0
011 APCX
MVZPFR
DZRN SZRN ABSX
[Size] 1 byte (bit type)
[Standard value] 1 only for APCX
ABSX Indicates whether the absolute position detector has been associated
with the machine position, as follows:
0 : Has not been associated
1 : Has been associated
SZRN Specifies the type of positioning to a grid to be performed for a manual
reference position return if the feed axis and direction selection signal
(+X, -X, or I/O link signal from the host) is 1 for reference position
return without dogs, as follows:
0 : Positioning to a grid is performed only once.
1 : Positioning to a grid is performed each time the feed axis and
direction selection signal becomes 1.
DZRN Specifies whether the reference position return function with dogs is
valid, as follows:
0 : Invalid. (The reference position return function without dogs is
selected.)
1 : Valid
CAUTION
When DZRN = 1, the high-speed interlock signal
(*RILK) is invalid.
MVZPFR On a rotation axis where the absolute-position detector is used, when
the reference position is updated and the value of the amount of
movement has a fractional part:
0 : The reference position is updated, making allowance for the
fractional part.
1 : The reference position is updated, without making allowance for
the fractional part.
NOTE
Set this parameter to 1 only when a rotation axis
uses the absolute-position detector, and a positional
error may occur, as described in the notes on
parameter No. 032. Otherwise, this parameter must