C.DIAGNOSIS LISTS APPENDIX B-65395EN/01
- 290 -
C.2 SIGNALS SENT FROM SERVO AMPLIFIER MODULE TO
CNC (HOST)
C.2.1 Peripheral Equipment Control Interface (DRC = 0)
(DGN No.) 7 6 5 4 3 2 1 0
016 OPC4 OPC3 OPC2 OPC1 INPX SUPX IPLX DEN2
017 OP SA STL UCPC2 OPTENB ZRFX DRCO ABSWT
018 MA AL DSP2 DSP1 DSALO TRQM RST ZPX
019
020
021
022
Response data
023 SVERX PSG2 PSG1 MVX APBAL MVDX
C.2.2 Direct Command Interface (DRC = 1)
(DGN No.) 7 6 5 4 3 2 1 0
016 INPX SUPX IPLX DEN2
017 OP SA STL OPTENB ZRFX DRCO WAT
018 MA AL TRQM RST ZPX
019 INPFO SVERX PSG2 PSG1 MVX APBAL MVDX
020 EBSY EOSTB ECF USR1 EOPC DAL ECONT
021 Direct command (function code)
022 Reserved Execution result
023 Direct command (response data 1)
024 Direct command (response data 2)
025 Direct command (response data 3)
026 Direct command (response data 4)
027 Direct command (response data 5)
028 Direct command (response data 6)
029 Direct command (response data 7)
030 Direct command (response data 8)
031 Direct command (response data 9)
NOTE
1 DGN numbers 016 to 031 correspond to signal
addresses Xx+0 to Xx+15, respectively.
2 DGN numbers 024 to 031 (signal addresses Xx+8 to
Xx+15) in the peripheral equipment control interface
are used as response area for the power mate CNC
manager.
3 See Section 2.2 of Part II for details of the signals.