2.SIGNAL DESCRIPTIONS HANDLING B-65395EN/01
- 42 -
2.2 SIGNALS (LISTED IN GROUPS)
* The following lists not only signals transferred via the I/O link
interface but also direct input/output signals such as *ESP, *-OT,
*+OT, *RILK, *DEC, and HDI.
* Each listed address is based on the I/O link assignment address of
each slave of the host.
Function list
Address
Group Signal name Symbol
Peripheral
equipment
Direct command
Reference
item
Preparation completion signal MA Xx+2#7 2.3.1
1
Servo preparation completion signal SA Xx+1#6 2.3.1
Emergency stop signal *ESP Yy+1#1 2.3.2
External reset signal ERS Yy+1#0 2.3.2
2
Reset in-progress signal RST Xx+2#1 2.3.2
Alarm signal AL Xx+2#6 2.3.3
3
Absolute pulse coder battery alarm
signal
APBAL Xx+7#1 Xx+3#1 2.3.3
4 Mode selection signal MD4,MD2,MD1 Yy+0#0 to Yy+0#2 2.3.4
5 Feed axis and direction selection signal +X,-X Yy+0#4,Yy+0#5 2.3.5
Remaining travel in-range signal DEN2 Xx+0#0 2.3.6
Distribution pulse signal IPLX Xx+0#1 2.3.6
Acceleration/deceleration pulse signal SUPX Xx+0#2 2.3.6
In-position signal INPX Xx+0#3 2.3.6
Servo positional deviation monitor
signal
SVERX Xx+7#6 Xx+3#6 2.3.6
Axis movement in-progress signal MVX Xx+7#2 Xx+3#2 2.3.6
Movement direction signal MVDX Xx+7#0 Xx+3#0 2.3.6
Area signal PSG1,PSG2 Xx+7#3,Xx+7#4 Xx+3#3,Xx+3#4 2.3.6
Speed control in-progress signal TRQM Xx+2#2 2.3.6
6
Function enable signal OPTENB Xx+1#3 2.3.6
Feedrate override signal *OV1 to *OV8 Yy+7#0 to Yy+7#3 Yy+2#0 to Yy+2#3 2.3.7
Manual rapid traverse selection signal RT Yy+7#7 Yy+2#7 2.3.7
Rapid traverse override signal ROV1,ROV2 Yy+7#4,Yy+7#5 Yy+2#4,Yy+2#5 2.3.7
7
Incremental feed signal MP1, MP2 Yy+7#4,Yy+7#5 -- 2.3.7
8 Interlock signal *ILK Yy+1#3 2.3.8
Reference position return completion
signal
ZPX Xx+2#0 2.3.9
9
Reference position establishment
signal
ZRFX Xx+1#2 2.3.9
Automatic operation start signal ST Yy+0#7 2.3.10
Automatic operation start in-progress
signal
STL Xx+1#5 2.3.10
Automatic operation signal OP Xx+1#7 2.3.10
10
Dry run signal DRN Yy+7#6 Yy+2#6 2.3.10