B-65395EN/01 HANDLING 3.PERIPHERAL EQUIPMENT CONTROL
- 101 -
3.4.10 Teaching-based Data Setting Control
Host NC
CNC PMC
Servo amplifier module
operation state
+X
-X
position to be set is
indexed.
Jog mode
Start enabled state
Function code = 15
(1)
Start of data setting
Processing
by PMC
Command data 2 (point number)
The current value (absolute
coordinate) is set in the
parameter for the point number
specified in command data 2.
Start enabled state
ST signal
(2)
Operation completion
si
nal OPC 4
Operation completion signal OPC 1 End of ST signal acceptance
End of data setting
(3)
(1) After function code setting, the host NC indexes a position
according to the +X/-X signal.
(2) In data setting, the PMC on the host NC sets the function code and
command data 2, then sends the ST signal to the servo amplifier
module. Upon receipt of command data 2, the servo amplifier
module returns the operation completion signal OPC 1 to the host
NC.
(3) Upon the completion of setting the current value in a parameter,
the servo amplifier module returns the operation completion signal
OPC 4, and is placed in the start enabled state.
Supplementary information
1) The coordinate for a point number is set in the parameter area.
2) Perform teaching-based data setting while no movement is being
performed along the axes.
3) The start enabled state is that state in which the STL signal is off.