B-65395EN/01 APPENDIX B.PARAMETER LIST
- 245 -
CAUTION
The amount of motor revolution corresponding to
the amount of movement per rotation axis revolution
must be 2500 revolutions or less. If the amount of
motor revolution corresponding to the amount of
movement per rotation axis revolution exceeds
2500 revolutions, reduce the amount of motor
revolution to 2500 or below, by reducing the gear
reduction ratio or by other means.
No
142 Positive machine coordinate for stored stroke limit 1
No
143 Negative machine coordinate for stored stroke limit 1
[Size] 4-byte
[Unit of data] User-specified unit
[Valid data range] 0 to ±99999999
[Standard value] 99999999 (positive machine coordinate),
-99999999 (negative machine coordinate)
[Description] Sets up the positive and negative machine coordinates for stored stroke
limit 1. Areas outside the specified ranges are forbidden areas.
No
144 Machine coordinate for the second reference position
No
145 Machine coordinate for the third reference position
[Size] 4-byte
[Unit of data] User-specified unit
[Valid data range] 0 to ±99999999
[Standard value] 0
[Description] Sets up the machine coordinates for the second and third reference
positions.
No
147 Workpiece coordinate for the reference position
[Size] 4-byte
[Unit of data] User-specified unit
[Valid data range] 0 to ±99999999
[Standard value] 0
[Description] Sets up the workpiece coordinate for the reference position. When
setting the reference position, either without dogs or externally, is
completed, the workpiece coordinate of the reference position is preset
to the value specified in the parameter. This parameter is fixed to 0 for
the rotation axis.