B-65395EN/01 APPENDIX B.PARAMETER LIST
- 269 -
No
031 Direction of motor rotation (DIRCTL)
[Size] 1 byte
[Standard value] 111
The direction of motor rotation is specified, as follows:
111: Normal connection (clockwise rotation as viewed from the
detector side)
-111: Reverse connection (counterclockwise rotation as viewed from
the detector side)
No
032 Command multiplier (CMR)
[Size] 1 byte
[Valid data range] 2 to 96, 102 to 127
NOTE
Only even numbers in the range of 2 to 96 can be
set.
[Standard value] 2
This parameter is used to set up a ratio of the user-specified unit to the
detection unit.
Let K be the user-specified unit divided by the detection unit, then
enter:
CMR = 2 × K if K ≥ 1
CMR = 1/K + 100 if K < 1
where K is a value from 1 to 48 or from 1/2 to 1/27.
Example 1)
If the least command increment is 10 µm, and the detection
increment is 5 µm:
CMR=10/5×2=4
Example 2)
If the least command increment is 10 µm, and the detection
increment is 20 µm:
CMR = 1/(1/2) + 100 = 102
because K = 10/20 < 1