B-65395EN/01 HANDLING 2.SIGNAL DESCRIPTIONS
- 63 -
(4) Command data
[Classification] Output signal <Yy+6 to Yy+15>
[Function] The host provides data for a function code command.
[Operation] The servo amplifier module behaves as directed by the function code
command when receiving it.
See "Direct command function details" for details.
(5) Response data
[Classification] Input signal <Xx+7 to Xx+15>
[Function] (A) The servo amplifier module returns the result of function code
command execution.
(B) The servo amplifier module returns the data requested by the
function code.
(C) The servo amplifier module outputs continuous-output data, such
as the current position, requested by the continuous read
command.
[Input condition] (A) The servo amplifier module returns the result of function code
command execution.
It is possible to defer the return of the result of each function code
command and return their results at the same time, if they are of a
type that can be buffered.
(B) The servo amplifier module outputs data, such as alarm
information, requested by the function code.
(C) If the host is to receive data, such as the current position, that is
being monitored continuously, the servo amplifier module
continues to output the requested data in response to a single
request.
After setting the above data or result, the servo amplifier module
inverts the state of EOSTB. They can be read when the result of
exclusive-ORing EOREND with EOSTB is 1. EOPC indicates
that the current data is of continuous output type. When EOPC is 0,
it indicates data covered in (A) or (B). When it is 1, it indicates
data covered in (C).
(6) Continuously output data signal EOPC
[Classification] Input signal <Xx+4#2>
[Function] The servo amplifier module indicates that continuously output data
requested using a function code command is being output as response
data.
[Input condition] The signal becomes 1 when:
1. Continuously output data requested by a function code command
is being output as response data.
The signal becomes 0 when:
1. Data other than continuously output data requested by a function
code command is being output as response data.