B–61803E–1/10
7. Series 16/18 2–PATH DEDICATED
CONTROL FUNCTION
PROGRAMMING
161
When macro executor ROM are mounted on tool posts 1 and 2, the
conversational macro of the macro executor of tool post 1 can be
executed, regardless of which tool post selects the conversational macro
screen.
Set compilation parameter TTDSP (No. 9007, #0) to 1 for the executor
of tool post 2. Set parameters 9038, 9040, and 9041 to the same values
as in tool post 1. The conversational macro program of tool post 1 is
executed even when the
CUSTOM
key is pressed while tool post 2 is being
selected.
If the parameter is set to 0, the conversational macro programs selected
by the heads of tool posts 1 and 2 are executed separately.
TTDSP=1 : The common conversational macro screen is validated.
NOTE
This function cannot be executed when the function for
leaving the screen unchanged when the key is pressed
(Section 6.27) is executed.
CUSTOM
7.1
COMMON
CONVERSATIONAL
MACRO SCREEN