(a) INPUT UNIT : Handle interrupt move amount in input unit
system
Indicates the travel distance specified by handle
interruption according to the least input
increment.
(b) OUTPUT UNI : Handle interrupt move amount in output unit
system
Indicates the travel distance specified by handle
interruption according to the least command
increment.
(c) RELATIVE : Position in relative coordinate system
These values have no effect on the travel distance
specified by handle interruption.
(d) DISTANCE TO GO : The remaining travel distance in the current
block has no effect on the travel distance
specified by handle interruption.
The handle interrupt move amount is cleared when the manual reference
position return ends every axis.
By setting bit 2 (IHD) of parameter No. 7100 and bit 5 (HIE) of parameter
No. 7103 to 1, acceleration/deceleration for manual handle interruption
can always be of the acceleration/deceleration type for manual feed,
without being affected by automatic operation or some other mode.
More specifically, the acceleration/deceleration type set with bit 4 (JGLx)
of parameter No. 1610 and bit 0 (CTLx) of parameter No. 1610 is applied.
Set a time constant with parameter No. 1624, and an FL feedrate with
parameter No. 1625.
D Independent
acceleration/deceleration