APPENDIXG. ALARM LIST
B–64124EN/01
858
4) Serial pulse coder (SPC) alarms
No. Message Description
360 n AXIS : ABNORMAL CHECKSUM
(INT)
A checksum error occurred in the built–in pulse coder.
361 n AXIS : ABNORMAL PHASE DATA
(INT)
A phase data error occurred in the built–in pulse coder.
362 n AXIS : ABNORMAL REV.DATA
(INT)
A rotation speed count error occurred in the built–in pulse coder.
363 n AXIS : ABNORMAL CLOCK (INT) A clock error occurred in the built–in pulse coder.
364 n AXIS : SOFT PHASE ALARM (INT) The digital servo software detected invalid data in the built–in pulse
coder.
365 n AXIS : BROKEN LED (INT) An LED error occurred in the built–in pulse coder.
366 n AXIS : PULSE MISS (INT) A pulse error occurred in the built–in pulse coder.
367 n AXIS : COUNT MISS (INT) A count error occurred in the built–in pulse coder.
368 n AXIS : SERIAL DATA ERROR
(INT)
Communication data from the built–in pulse coder cannot be re-
ceived.
369 n AXIS : DATA TRANS. ERROR
(INT)
A CRC or stop bit error occurred in the communication data being
received from the built–in pulse coder.
380 n AXIS : BROKEN LED (EXT) The separate detector is erroneous.
381 n AXIS : ABNORMAL PHASE
(EXT LIN)
A phase data error occurred in the separate linear scale.
382 n AXIS : COUNT MISS (EXT) A pulse error occurred in the separate detector.
383 n AXIS : PULSE MISS (EXT) A count error occurred in the separate detector.
384 n AXIS : SOFT PHASE ALARM
(EXT)
The digital servo software detected invalid data in the separate de-
tector.
385 n AXIS : SERIAL DATA ERROR
(EXT)
Communication data from the separate detector cannot be received.
386 n AXIS : DATA TRANS. ERROR
(EXT)
A CRC or stop bit error occurred in the communication data being
received from the separate detector.
387 n AXIS : ABNORMAL ENCODER
(EXT)
An error occurs in the separate detector. For details, contact the
manufacturer of the scale.