OPERATION11. SETTING AND DISPLAYING DATA
B–64124EN/01
690
LIFE DATA EDIT GROUP : 001 O0010 N00001
TYPE : 1 (1:C 2:M) NEXT GROUP: ***
LIFE : 9800 USE GROUP : ***
COUNT : 6501 SELECTED GROUP : 001
NO. STATE T–CODE H–CODE D–CODE
01 * 0034 011 005
02 # 0078 000 033
03 @ 0012 004 018
04 * 0056 000 000
05 0090 000 000
06 * 0076 023 012
> _
MDI **** *** *** 16:05:59
[ INSERT ] [ DELETE ] [ STATE ] [ END ] [ INPUT ]
NEXT GROUP :
Number of the tool group whose life is to be calculated by the next M06
command
USE GROUP :
Number of the tool group whose life is being calculated
SELECTED GROUP :
Number of the tool group whose life is being calculated or was calculated
last
TYPE: 1: Life count is represented in units of cycles.
TYPE: 2 : Life count is represented in units of minutes.
LIFE : Life expectancy
COUNT : Life counter
STATE : State of the tool
Tool state In use Not in use
Available @ _(Space)
Skip q
Skipped :
NOTE
When bit 3 (EMD) of parameter 6801 is set to 0, @ is
displayed until the next tool is selected.
T–CODE : Tool number
H–CODE : H code
D–CODE : D code
Explanations
D Displays
#
w /
(Note)
: