OPERATION
B–64124EN/01
11. SETTING AND DISPLAYING DATA
675
This value is incremented by one when M02, M30, or an M code specified
by parameter 6710 is executed. The value can also be set by parameter
6711. In general, this value is reset when it reaches the number of parts
required. Refer to the manual issued by the machine tool builder for
details.
Displays the total time which the power is on. This value cannot be set
on this screen but can be preset in parameter 6750.
Indicates the total run time during automatic operation, excluding the
stop and feed hold time.
This value can be preset in parameter 6751 or 6752.
Displays the total time taken by cutting that involves cutting feed such as
linear interpolation (G01) and circular interpolation (G02 or G03). This
value can be preset in parameter 6753 or 6754.
This value can be used, for example, as the total time during which coolant
flows. Refer to the manual issued by the machine tool builder for details.
Indicates the run time of one automatic operation, excluding the stop and
feed hold time. This is automatically preset to 0 when a cycle start is
performed at reset state. It is preset to 0 even when power is removed.
Displays the current date and time. The date and time can be set on this
screen.
When the command of M02 or M30 is executed, the total number of
machined parts and the number of machined parts are incremented by one.
Therefore, create the program so that M02 or M30 is executed every time
the processing of one part is completed. Furthermore, if an M code set
to the parameter (NO. 6710) is executed, counting is made in the similar
manner. Also, it is possible to disable counting even if M02 or M30 is
executed (parameter PCM (No. 6700#0) is set to 1). For details, see the
manual issued by machine tool builders.
Negative value cannot be set. Also, the setting of “M” and “S” of run time
is valid from 0 to 59.
Negative value may not be set to the total number of machined parts.
Neither negative value nor the value exceeding the value in the following
table can be set.
Item Maximum value Item Maximum value
Year 2085 Hour 23
Month 12 Minute 59
Day 31 Second 59
D PARTS COUNT
D POWER ON
D OPERATING TIME
D CUTTING TIME
D FREE PURPOSE
D CYCLE TIME
D DATA and TIME
Limitations
D Usage
Restrictions
D Run time and part count
settings
D Time settings