OPERATION
B–64124EN/01
5. TEST OPERATION
515
M, S, T and B commands are executed in the machine lock state.
When a G27, G28, or G30 command is issued in the machine lock state,
the command is accepted but the tool does not move to the reference
position and the reference position return LED does not go on.
M00, M01, M02, M30, M98, M99, and M198 (Subprogram call)
commands are executed even in the auxiliary function lock state. M codes
for calling a subprogram (parameters No. 6071 to 6079) and those for
calling a custom macro (parameter No. 6080 to 6089) are also executed.
Restrictions
D M, S, T, B command by
only machine lock
D Reference position
return under Machine
Lock
D M codes not locked by
auxiliary function lock