6. AC SPINDLE (SERIAL INTERFACE)
B–62835EN/01
236
Numerals are parameter numbers :
Proportional gain(HIGH) 4040
Proportional gain (LOW) 4041
Integral gain(HIGH) 4048
Integral gain(LOW) 4049
Motor voltage 4083
Regenerative power 4080
Numerals are parameter numbers :
Proportional gain(HIGH) 4042
Proportional gain (LOW) 4043
Integral gain(HIGH) 4050
Integral gain(LOW) 4051
Position loop gain(HIGH) 4060
Position loop gain (MID,HIGH) 4061
Position loop gain (MID,LOW) 4062
Position loop gain(LOW) 4063
Motor voltage 4084
Change of position gain 4064
Stop position shift amount 4077
Orientation by PC method 4031
Numerals are parameter numbers :
Proportional gain(HIGH) 4044
Proportional gain (LOW) 4045
Integral gain(HIGH) 4052
Integral gain(LOW) 4053
Position loop gain(HIGH) 4065
Position loop gain (MID,HIGH) 4066
Position loop gain (MID,LOW) 4067
Position loop gain(LOW) 4068
Motor voltage 4085
ZRN gain % 4091
Grid shift amount 4073
6.4.5
Correspondence
Between Operation
Mode and Parameters
on Spindle Tuning
Screen
D Speed control mode
(Normal mode)
D Spindle orientation mode
D Rigid tapping mode