1. DISPLAY AND OPERATION
B–62835EN/01
32
The system configuration screen and the state display etc. are not prepared
on the DPL/MDI.
With the CRT/MDI, the following numbers cannot be used for reference.
Therefor, see the following diagnostic number.
Diagnostic No. Unit
800 Relative coordinates Least input increment
801 Skip position Least input increment
802 Remaining travel (Least input increment)/2
803 Acceleration/deceleration
accumulation
Detection unit
804 Ending position of previous
block
(Least input increment)/2
810 Number of program being
executed
811 Number of sequence being
executed
820 Group 01 G–code
821 Group 02 G–code
822 Group 03 G–code
823 Group 05 G–code
824 Group 06 G–code
825 Group 08 G–code
826 Group 09 G–code
827 Group 10 G–code
830 F–code being executed Unit: 0.001 mm/min or
0.00001 inch/m
(When no decimal point is
entered, units are 1 mm/min
or 0.01 inch/min.)
831 Actual feedrate Unit: mm/min, deg/min, or
0.01 inch/min
832 Actual spindle speed Unit: rpm
833 Corrected version of a value in-
put using the analog input
function
Unit: 10mV
840 Number of registered blocks Unit: Blocks
841 Amount of memory used by
program
Unit: Characters
850 ROM series No. of NC system
(Example) 8834
851 ROM version No. of NC system
(Example) 01, 02, etc.
852 Operation mode
(Example) AUTO, JOG, STEP, EDIT, etc.
853 Servo system series No.
(Example) 9060
854 Servo system version No. (Ex-
ample) 09, 10, etc.
855 PMC system series No.
(Example) 4075
1.6.4
Contens Displayed