B–62835EN/01
1. DISPLAY AND OPERATION
35
This function displays the key and signal operations performed by the NC
operator upon the occurrence of a fault or the output of an NC alarm,
together with the corresponding NC alarms.
Operation history information cannot be displayed on the DPL/MDI. The
Power Mate–F is not provided with an operation history function.
This function records the following data:
(1) MDI key operations performed by the NC operator
(2) Status changes (ON/OFF) of input and output signals (selected
signals only)
(3) Details of NC alarms
(4) Time stamp (date and time)
(1) Press the
SYSTEM
function key.
(2) Press the continue menu key [
]. The [OPEHIS] (operation
history) soft key are displayed.
(3) Press the [OPEHIS] soft key twice. The operation history screen is
displayed.
OPERATION HISTORY O1234 N12345
Page : 123
No.DATA No.DATA No.DATA
01 92/06/03 11 F0000.7↑ 21 F0001.0↓
02 08:40:00 12 F0000.5↑ 22 <POS>
03 <DELETE> 13 F0001.0↑ 23 <PROG>
04 F0000.6↑ 14 F0000.5↓ 24 <RESET>
05 MEM 15 P/S0010 25 EDIT
06 G0009.0↑ 16 92/06/03 26 O
07 G0009.1↑ 17 09:27:49 27 1
08 G0009.2↑ 18 <PROG> 28 2
09 ST↑ 19 <RESET> 29 3
10 ST↓ 20 F0000.7↓ 30 4
EDIT **** *** *** 08:20:52
[ TOP ][ BOTTOM ][ ][ ][PG.SRH]
On the operation history screen, the soft keys are configured as shown
below:
⇒ [ ][PARAM ] [DGNOS] [PMC] [SYSTEM] [(OPRT)][ ]
ãpush
[
] [W.DGNS] [ ] [ ] [OPEHIS] [(OPRT)][ ]
ã push
[
][
OPEHIS
] [SG–SEL] [ ] [ ] [(OPRT)][ ]
ãpush
[
] [ TOP ] [BOTTOM] [ ] [ ] [PG.SRH] [ ]
1.8
OPERATION HISTORY
1.8.1
Screen Display
D Displaying the operation