B–62835EN/01
1. DISPLAY AND OPERATION
31
#7 #6 #5 #4 #3 #2 #1 #0Address
0409 SPE S1E SHE
DGN
Refer to this diagnosis when alarm 750 has generated.
#3 (SPE) In spindle serial control serial spindle parameters
0 : Satisfy start condition of spindle unit
1 : Do not satisfy start condition of spindle unit
#1 (S1E) 0 : 1st spindle started normally in spindle serial control.
1 : 1st spindle did not start normally in spindle serial control.
#0 (SHE) 0 : The module needed for spindle serial control on the CNC side is
normal.
1 : An abnormal condition occurred in the module needed for spindle
serial control on the CNC side.
0410 Load meter of 1st spindle [%]
DGN
0411 Speed meter of 1st spindle [%]
DGN
0417 Feedback information of 1st spindle position coder
DGN
0418 Position error of 1st spindle position loop mode
DGN
450 Spindle position error during rigid tapping
DGN
[Data type] Word
[Unit of data] Detection units
451 Spindle distribution during rigid tapping
DGN
[Data type] Word
[Unit of data] Detection units
454 Accumulated spindle distribution during rigid tapping
DGN
[Data type] Two–word
[Unit of data] Detection units
D Diagnostic data related
to rigid tapping