B--65245EN/02
3. PERIPHERAL EQUIPMENT CONTROLHANDLING
85
Set a speed deviation check limit value in the speed control mode. If the
difference between a command speed and actual speed exceeds the value
set in this parameter in the speed control mode, alarm 447 is issued.
#7 #6 #5 #4 #3 #2 #1 #0
Xx+2 TRQM
TRQM <Input signal> Speed control mode signal
0 : The speed control stop command sets this signal to 0
to terminate the speed control m ode. This signal i s
also set to 0 by a servo alarm or emergency stop to
terminate the speed control mode.
1 : The speed control mode is currently set.
No. LED indication Description Action
254
Function code is invalid. Check the value specified as the function
code of a function code command.
255
Activation is impossible because the activa-
tion mode is different or a block is being
executed.
Check the mode. Check if a block is being
executed.
447
Excessive speed deviation (speed control) Check the actual speed. Check the setting of
parameter No. 136.
(1) To exercise speed control, the parameters below usually need to be
modified.
Do not modify parameters other than the parameters below.
Bit 1 of No. 000: Set this bit to 1 (rotation axis specification).
Bit 7 of No. 000: Set t his bit to 1 (to enable rotation axis roll--over).
No. 080: Set a current limit value of 7282.
No. 100: Load inertia ration. S et an adjusted value.
The parameters below are dedicated to speed control. So, once these
parameters are set, they need not be modified each time control is
switched to speed control.
No. 116: Velocity loop gain override in speed control. (Set this
parameter when switching between position control and
speed control.)
No. 135: Linear acceleration/deceleration time constant for speed
control
No. 136: Speed deviation check limit value in speed control
(2) In the speed control mode, the processing described below is
performed based on output signals.
3.4.6.6
Signal
3.4.6.7
Alarm
3.4.6.8
Others