B--65245EN/02
4. DIRECT COMMANDSHANDLING
115
(1) Reading the absolute position
The host can read the absolute position of the servo amplifier unit.
#7 #6 #5 #4 #3 #2 #1 #0
Yy+4 Control flag 1
Yy+5 00110000
(0x30)
Yy+6 00000001
#7 #6 #5 #4 #3 #2 #1 #0
Xx+4 Control flag 2
Xx+5 00110000
(0x30)
Xx+6 Reserved Execution result
Xx+7 Axis data (DWORD type)
Xx+8 Axis data (DWORD type)
Xx+9 Axis data (DWORD type)
Xx+10 Axis data (DWORD type)
(2) Reading the machine position
The host can read the machine position of the servo amplifier unit.
#7 #6 #5 #4 #3 #2 #1 #0
Yy+4 Control flag 1
Yy+5 00110001
(0x31)
Yy+6 00000001
#7 #6 #5 #4 #3 #2 #1 #0
Xx+4 Control flag 2
Xx+5 00110001
(0x31)
Xx+6 Reserved Execution result
Xx+7 Axis data (DWORD type)
Xx+8 Axis data (DWORD type)
Xx+9 Axis data (DWORD type)
Xx+10 Axis data (DWORD type)
4.4.3
Status Read
D Instruction command
format
D Response command
format
D Instruction command
format
D Response command
format