B--65245EN/02
B. PARAMETERSAPPENDIXES
191
#7 #6 #5 #4 #3 #2 #1 #0
005 ABSPS LDM REFDRC CLPSVF JNCL
Size : 1 byte (bit type)
Standard value :0
JNCL Specifies whether to use clamping when JOG operation
stops, as follows:
0 : Clamping is performed.
1 : Clamping is not performed. (The unclamp state is
preserved.)
CLPSVF The time from clamping to servo off (parameter No. 168)
is:
0 : Time from the point the unclamping i nstruction signal
(UCPC2) turns off
1 : Time from the point the clamping/unclamp state
output signal (UCPS2) turns off.
REFDRC The direction of the high--speed origin return of the
rotation axis depends on:
0 : Sign of the result of subtracting the current position
from the reference position.
1 : Setting of ZMIX (bit 5 of parameter No. 010).
LDM Specifies whether the output of the motor current value is
valid to the response data (Xx+3 to Xx+6), as follows:
0 : Invalid.
1 : Valid.
ABSPS Specifies whether the host and a servo amplifier unit are
to be synchronized with each other in the response data
read function, as follows:
0 : Not synchronized.
1 : Synchronized. (This makes it possible for the host to
read the correct position even during axis movement.)
NOTE
For details, see Part 2, Section 3.8, “Upgrading the
Response Data Read Function.”