2. SIGNAL DESCRIPTIONS
B--65245EN/02
HANDLING
50
(1) Interlock signal *ILK
[Classification]
Input signal <Yy+1#3> (common to both the peripheral equipment
control and direct command interfaces)
[Function]
The host stops sending all movement commands.
[Input condition]
When the *ILK signal is 0, the host resets all movement command
signals to 0 to decelerate and stop controlled axis feed. Movement
commands remain valid when the *ILK signal is 0. When it becomes
1, movement is resumed immediately. No command other than a
move command is affected.
NOTE
The interlock signal is valid in jog feed mode (JOG).
(1) Reference position return completion signal ZPX
[Classification]
Input signal <Xx+2#0> (common to both the peripheral equipment
control and direct command interfaces)
[Function]
The servo amplifier unit indicates that it is at the reference position.
[Input condition]
The signal becomes 1 when:
1. Manual reference position return is completed, and the servo
amplifier unit enters the in--position state.
2. Function code command--based reference position return is
completed, and t he servo amplifier unit enters the in--position
state.
The signal becomes 0 when:
1. The servo amplifier unit moves out of the reference position.
(1) Automatic operation start signal ST
[Classification]
Input signal <Yy+0#7> (common to both the peripheral equipment
control and direct command interfaces)
[Function]
The host starts function code commands, such as part of peripheral
equipment control ATC operations and point positioning.
Specifically, the host issues a direct command to start 32--block
buffering.
[Operation]
When the ST signal is set to 1 then reset to 0 again, the servo amplifier
unit begins operating. Section 3.3.1 explains the function codes for
which the ST signal is valid in peripheral equipment control.
2.3.8
Interlock
2.3.9
Reference Position
Return
2.3.10
Automatic Operation