B-65245EN/02-8
6/11
EDIT
DATE DESIG.
DESCRIPTION
FANUC SERVO MOTOR β series I/O Link Option
Skip Function (Improvement of the specification) and
CAUTION to the parameters No.068, 141
TITLE
DRAW.NO. CUST.
SHEET
01
04.05.06
Newly added
(3) Reading the measuring data by skip function
The host can read the measuring data by skip function in the servo unit.
(This function can be used after skip function is executed.)
Instruction command format
Response command format
Please add the following between “4.4.3. Status read (2) Reading the machine position”
and “4.4.3. Status read (3) Reading the servo delay” in the subsection 4.4 DETAIL OF
DIRECT COMMANDS FUNCTIONS of II HANDLING 4. DIRECT COMMANDS. And change
the item number “(3) to (9)” to “(4) to (10)”.
#7 #6 #5 #4 #3 #2 #1 #0
Yy+4 Control flag 1
Yy+5 0 0 1 1 0 0 1 0
(0x32)
Yy+6 0 0 0 0 0 0 0 1
#7 #6 #5 #4 #3 #2 #1 #0
Yy+4 Control flag 2
Yy+5 0 0 1 1 0 0 1 0
(0x32)
Yy+6 Reserved Execution result
Yy+7
Yy+8 Axis data (DWORD type)
Yy+9 (Measuring data: Workpiece coordinate value)
Yy+10