B--65245EN/02
2. CONFIGURATIONSTART--UP PROCEDURE
5
The basic configuration is shown below. For details, refer to the ”FANUC
Servo Motor
ϒ Series S ervo Descriptions (B--65232EN).”
Example of two servo amplifier units for two axes
Host controller
CNC or PLC
I/O link
Control power 24 VDC +10%
Servo amplifier
unit
ϒ series
SVU
(I/O link option)
Servo amplifier
unit ϒ series
SVU
(I/O link option)
Circuit
breaker
AC
line
filter
Magnetic
contactor
(NOTE 1) (NOTE 2) (NOTE 3)
Servo
motor
Servo
motor
Basic
Option
Equipment to be prepared by the machine tool builder
3∞ AC200 to 240V
Ν∞ AC220 to 240V
NOTE
1 The circuit breaker is used to protect the power cable, servo amplifier units, and so forth.
2 An AC line filter must be used to reduce the influence of harmonic noise on the power supply.
When a power transformer (in sulation type) is used because the input power supply voltage
is outside the specified range, no AC line filter is required. If harmonic noise cannot be
suppressed sufficiently to satisfy EMC requirements, use a commercially available noise filter.
3 Be sure to install an electromagnetic contactor.
4 At the power inlet of the power magnetics cabinet, install a surge absorber between lines and
between each line and ground to protect the equipment from surge voltages caused by
lightning.
2.1
BASIC