3. PERIPHERAL EQUIPMENT CONTROL
B--65245EN/02
HANDLING
66
The servo amplifier unit receives a command, issued in the specified
format, from the host, then executes a sequence of operations for
performing peripheral equipment control. When a command for reading
the current position is specified, the servo amplifier unit returns the result
of command execution to the host. The command and result are
exchanged, in an interface area, in the formats shown below.
#7 #6 #5 #4 #3 #2 #1 #0
Yy+2 Function code Command data 1
Yy+3
Yy+4 Command data 2
Yy+5
Yy+6
#7 #6 #5 #4 #3 #2 #1 #0
Xx+3
Xx+4 Response data
Xx+5
Xx+6
#7 #6 #5 #4 #3 #2 #1 #0
Byte type
(BYTE):
#7 #6 #5 #4 #3 #2 #1 #0
Lower byte
Word type
(WORD):
Higher byte
Data = (higher byte)*256 + (lower byte)
#7 #6 #5 #4 #3 #2 #1 #0
Lowest byte
Double precision type
(DWORD):
Second lowest byte
Second highest byte
Highest byte
Data = (highest byte)*16777216
+ (second highest byte)* 65536
+ (second lowest byte)*256
+(lowestbyte)
3.1
COMMAND FORMAT
FOR PERIPHERAL
EQUIPMENT
CONTROL
D Ge neral format of
instruction commands
(host servo amplifier
unit)
D Ge neral format of
response commands
(servo amplifier unit
host)
D Data types