B--65245EN/02
4. DIRECT COMMANDSHANDLING
125
Axis movement commands are executed in AUTO mode.
CAUTION
Do not change the mode during operation. Change the
mode only after operation stops.
(1) Reference position return
This command instructs the servo amplifier unit to perform reference
position return. When the reference position has not yet been
established, movement is performed in the reference position return
direction (bit 5 (ZMIX) of parameter No. 010) at low speed (set in
parameter No. 054), then stops at the first grid point. This position i s
set as the reference position.
When the reference position has already been established, return to
the reference position is performed at high speed (rapid traverse rate).
#7 #6 #5 #4 #3 #2 #1 #0
Yy+4 Control flag 1
Yy+5 01100000
(0x60)
Yy+6 0000NMOD000
Yy+7 00000001
NMOD = 1: Execution completion notification mode
(For details, see Section 4.2.)
This command has no response data.
4.4.4
Axis Movement
Commands
D Instruction command
format
D Response command
format