4. DIRECT COMMANDS
B--65245EN/02
HANDLING
116
(3 ) Reading the servo delay
The host can read the servo delay in the servo amplifier unit.
#7 #6 #5 #4 #3 #2 #1 #0
Yy+4 Control flag 1
Yy+5 00110011
(0x33)
Yy+6 00000001
#7 #6 #5 #4 #3 #2 #1 #0
Xx+4 Control flag 2
Xx+5 00110011
(0x33)
Xx+6 Reserved Execution result
Xx+7 Axis data (DWORD type)
Xx+8 Axis data (DWORD type)
Xx+9 Axis data (DWORD type)
Xx+10 Axis data (DWORD type)
(4 ) Reading the servo acceleration/deceleration delay
The host can read the servo acceleration/deceleration delay in the
servo amplifier unit.
#7 #6 #5 #4 #3 #2 #1 #0
Yy+4 Control flag 1
Yy+5 00110100
(0x34)
Yy+6 00000001
#7 #6 #5 #4 #3 #2 #1 #0
Xx+4 Control flag 2
Xx+5 00110100
(0x34)
Xx+6 Reserved Execution result
Xx+7 Axis data (DWORD type)
Xx+8 Axis data (DWORD type)
Xx+9 Axis data (DWORD type)
Xx+10 Axis data (DWORD type)
D Instruction command
format
D Response command
format
D Instruction command
format
D Response command
format