D. POWER MA TE CNC
MANAGER FUNCTIONS
B--65245EN/02
APPENDIXES
230
1. Select an active slave.
2. Press the [(OPRT)] soft key to display:
[NO.SRC] [ ] [ ] [ ] [INPUT]
Press the next--menu key.
[ ] [ READ ] [PUNCH] [ ] [ ]
3. Press the [READ] soft key to display:
[ ] [ ] [ ] [CANCEL] [ EXEC ]
Press the [EXEC] soft key.
While the parameters are being saved, the message ”INPUT”
blinks on the message line.
(4) Writing parameters
Parameter data files saved as programs to the CNC memory or
memory CAD can be restored and written to the servo amplifier unit
determined from a program number. The program number and device
are determined using the same method as in item (3).
1. Select an active slave.
2. Press the [(OPRT)] soft key to display:
[NO.SRC] [ ] [ ] [ ] [INPUT]
Press the next--menu key.
[ ] [ READ ] [PUNCH] [ ] [ ]
3. P ress the [PUNCH] soft key to display:
[ ] [ ] [ ] [CANCEL] [ EXEC ]
Press the [EXEC] soft key.
While the parameters are being written, the message ”OUTPUT”
blinks on the message line.
(5) Searching for parameters
A parameter can be searched for and displayed by means of the
following procedure.
1. Select an active slave.
2. Press the [(OPRT)] soft key to display:
[NO.SRC] [ ] [ ] [ ] [INPUT]
3. Key in a desired number on the key--in line using the MDI
keypad, then press the [NO.SRC] soft key to start the search.