2. SIGNAL DESCRIPTIONS
B--65245EN/02
HANDLING
52
NOTE
When the signal described below is used, the external pulse
input function cannot be used.
(1) Unclamp command signal UCPC2
[Classification]
Input signal <Xx+1#4>
[Function]
The host is responsible for clamping and unclamping the machine.
The servo amplifier unit issues this signal to request the host to
clamp/unclamp the machine when a peripheral equipment control
function code command is executed.
[Input condition]
The signal is set to 1 when a request is issued to the host to unclamp
the machine. It is reset to 0 when a request is issued to the host to
clamp the machine. The servo amplifier unit sets the UCPC2 signal
to 1 when i t starts executing commands with function codes 0 and 2
to 6. When the m ove command is terminated, the UCPC2 signal is
reset to 0. See the timing chart for the function codes for peripheral
equipment control.
NOTE
The UCPC2 signal is valid when the NCLP parameter (bit
1 of parameter No. 003) is 0.
(2) Clamp/unclamp state output signal UCPS2
[Classification]
Output <Yy+0#6>
[Function]
When the servo amplifier unit requests clamping/unclamping of the
machine, using the UCPC2 signal, the host actuallyclamps/unclamps
the machine. Upon the completion of clamping/unclamping, it
reports it to the servo amplifier unit, which then proceeds to the next
processing.
[Operation]
The signal is set to 1 when the machine is unclamped. When it i s
clamped, the signal is reset to 0. See the timing chart for the function
codes for peripheral equipment control.
NOTE
The UCPS2 signal is valid when the NCLP parameter (bit 1
of parameter No. 003) is 0.
2.3.11
Clamp and Unclamp
(for the Peripheral
Equipment Control
Interface Only)