4. DIRECT COMMANDS
B--65245EN/02
HANDLING
128
(4) Dwell
This command instructs the servo amplifier unit t o perform dwell.
The execution of the next block can be delayed by a specified amount
of time.
#7 #6 #5 #4 #3 #2 #1 #0
Yy+4 Control flag 1
Yy+5 01100011
(0x63)
Yy+6 0000NMOD001
Yy+7 00000001
Yy+8 DWELL TIME
Yy+9 DWELL TIME
Yy+10 DWELL TIME
Yy+11 DWELL TIME
DWELL TIME : 1 to 99999999 (msec)
NMOD =1 : Execution completion notification mode
(For details, see Section 4.2.)
This command has no response data.
(5) Setting a coordinate system
The absolute position of t he servo amplifier unit i s preset at a
specified coordinate value.
#7 #6 #5 #4 #3 #2 #1 #0
Yy+4 Control flag 1
Yy+5 01100100
(0x64)
Yy+6 0000NMOD001
Yy+7 00000001
Yy+8 COORDINATE VALUE
Yy+9 COORDINATE VALUE
Yy+10 COORDINATE VALUE
Yy+11 COORDINATE VALUE
COORDINATE VALUE:
--99999999 to 99999999 (user--specified unit)
NMOD =1 : Execution completion notification mode
(For details, see Section 4.2.)
This command has no response data.
D Instruction command
format
D Response command
format
D Instruction command
format
D Response command
format