B–63294EN/021. OVERVIEW OF Super CAPi M
– 72 –
1.6.2 Alarms raised during NC statement output
When a machining program is converted to an NC statement program, it is also executed at the same time for
machining operation or drawing. Therefore, a P/S alarm may be raised, depending on the contents of the ma-
chining program or operation started.
When a P/S alarm is raised, correct the machining program by referring to the NC operator’s manual.
If a P/S alarm is raised during conversion, the NC statement program created thus far by conversion is stored
in a part program storage area. To convert the machining program again, first correct the machining program,
and delete the stored incomplete NC statement program. Then restart conversion operation from the begin-
ning.
The table below lists the alarms that may be raised during conversion.
Alarm No.
Description
070 Cause Memory is insufficient for part program storage.
Action Take action as described below.
1. When other NC statement programs are already stored, and the remaining memory size is
insufficient for the program being created by conversion:
å Save the other programs to an external storage unit via the reader/punch interface,
delete these programs, then restart the conversion operation from the beginning.
2. When the entire NC statement program storage area allocated is still insufficient for the
program being created by conversion:
å As described in the next section, output the NC program created by conversion to an
external storage unit. When the NC program created by
conversion is to be executed, use the DNC operation via the reader/punch interface.
The NC statement program storage area can be expanded by parameter setting. This
method, however, reduces the area for conversational programs, and also clears all
data temporarily. Therefore, this method should be used only when absolutely necessary.
072 Cause The number of registered programs exceeded 63, 125, 200, 400, or 1000 (option).
Action Save some of the NC statement programs already registered to an external storage unit via
the reader/punch interface, then delete these programs. Restart conversion from the begin-
ning, or output programs created by conversion to an external storage unit via the reader/
punch interface as described in the next section.
073 Cause An attempt was made to register a program number that is already registered.
Action Delete the existing NC statement program with the same program number, or change the pro-
gram number of the new program specified in conversion operation to a unique number, then
restart conversion from the beginning.