8. INTERLOCK
B–63443EN/02
PMC INTERFACE
154
This signal is used to inhibit the machine from moving, and is effective
regardless of the selected mode. When the *IT signal is “0”, the axis
movement is decelerated and stopped.
In automatic operation (cycle start lamp signal STL is “1”, feed hold lamp
signal SPL is “0”), blocks containing M, command is executed
consecutively until a block containing an axis move command is
encountered; the system then stops and is placed into the automatic
operation mode. When the *IT signal turns to “1”, operation resumes
(Figs. 8.1 (a), (b)).
Command read
*IT
Axis move
Fig.8.1 (a) Block Containing Only Axis Move Command
Command read
MF
FIN
*IT
Fig.8.1 (b) Block Containing Auxiliary Functions Only
(Automatic)
NOTE
The overtravel amount of the motor after turning *IT to “1”
is represented by the following formula.
Where
Qmax : Overtravel quantity (mm or inch)
Fm : Feedrate (mm/min or inch/min)
T
c
: Cutting time constant (msec)
T
s
: Servo time constant (Ts = 33msec normally)
A : Processing time of Power Mate
A =30ms
Qmax + F
m
.
1
60
(
T
C
1000
)
T
S
1000
)
A
1000
)
8.1
INTERLOCK SIGNAL
(INPUT) *IT<G008#0>